MSD Power Grid LED Indicator MSD Power Grid LED Indicator

MSD Power Grid LED Diagnostics


Quick reference guide to the MSD Power Grid's LED Indicator to troubleshoot error conditions. The LED is next to the USB card cover on the unit. When connecting the Power Grid to a Computer via the USB cable and you have the MSD View Software running, the LED indicator will initially be Orange for about 5 seconds, then switch to Solid Green with no power applied to the unit. It is getting it's power from the Computer USB cable.

LED CONDITION DESCRIPTION
Off Power Off
Green - Solid Power On, No Alerts
Green - Blinking Power On, Crank Trigger Input Active, Engine RPM > 500, No Alerts
Green - Solid USB Cable Connected to Computer, Power Off
Orange - for 5 Seconds Power On Test
Orange - for 10 Seconds 7761 ARC Connected
Orange - Blinking Recording Data
Red - Solid Power On, Crank Trigger Input Active, Engine RPM < 500, 1 or more alerts active
Red - Blinking Power On, Crank Trigger Input Active, Engine RPM > 500, 1 or more alerts active