MSD Power Grid LED Diagnostics
Quick reference guide to the MSD Power Grid's LED Indicator to troubleshoot error conditions. The LED is next to the USB card cover on the unit. When connecting the Power Grid to a Computer via the USB cable and you have the MSD View Software running, the LED indicator will initially be Orange for about 5 seconds, then switch to Solid Green with no power applied to the unit. It is getting it's power from the Computer USB cable.
LED CONDITION | DESCRIPTION |
---|---|
Off | Power Off |
Green - Solid | Power On, No Alerts |
Green - Blinking | Power On, Crank Trigger Input Active, Engine RPM > 500, No Alerts |
Green - Solid | USB Cable Connected to Computer, Power Off |
Orange - for 5 Seconds | Power On Test |
Orange - for 10 Seconds | 7761 ARC Connected |
Orange - Blinking | Recording Data |
Red - Solid | Power On, Crank Trigger Input Active, Engine RPM < 500, 1 or more alerts active |
Red - Blinking | Power On, Crank Trigger Input Active, Engine RPM > 500, 1 or more alerts active |